Numerical Protection Relays

Generator Protection Relay

The Siemens modular digital relay provide:

  • Short-circuit protection, including overcurrent, impedance, and differential schemes

  • Stator and rotor ground-fault detection (both directional and 100% coverage)

  • Under-/over-excitation protection, reverse-power protection, and unbalanced load detection

  • Over-/under-frequency and voltage protection, load decoupling, breaker failure, re‑closing, inadvertent energization prevention, and synchronization assistance

  • Flexible hardware supports up to 16 current transformers and 8 voltage transformers.

  • Ethernet (RJ45) interface with protocols including IEC 61850, Modbus, DNP3, Profinet, and redundancy features (PRP, HSR)

     

generator-protection-relays-siprotec-7um85.png

Transformer Protection Relay

Siemens transformer differential protection relay, designed specifically to safeguard two-winding transformers provides:

  • Transformer Differential Protection

  • Restricted Ground Fault (RGF) Protection

  • Overcurrent Protection

  • Over/Under Voltage Protection

  • Over/Under Frequency Protection

  • Overexcitation (V/Hz) Protection

  • Unbalanced Load Protection

  • Thermal Overload Protection

  • Arc Flash Detection

  • Breaker Failure Protection

  • Features built-in Ethernet and supports IEC 61850 (with GOOSE), IEC 60870-5-103/104, Modbus TCP, DNP3, and PROFINET IO via optional pluggable modules.

7sr54-transformer-500x500.webp

Feeder/Motor Protection Relay

Siemens protection relay provides:

feeder protecton relay.png
  • Directional & Non-Directional Overcurrent

  • ​Ground Fault Protection

  • Fault Locator

  • Arc Protection

  • Voltage & Frequency Protection

  • Capacitor Bank Protection

  • Breaker Management & Control

  • Fits a 1/3 × 19-inch module with I/O configurations ranging from 4 to 8 CT inputs and various binary I/O options.

  • Built-in Ethernet interface supports IEC 61850 (with GOOSE), and optional modules for IEC 60870, Modbus TCP, DNP3, PROFINET IO.

Protection Relays with Cyber Security

Siemens Protection Relays provides:

  • Phase Overcurrent (50/51)

  • Earth Fault Overcurrent (50N/51N)

  • Directional Overcurrent (67/67N)

  • Transformer Differential (87T)

  • Restricted Ground Fault (64R)

  • Distance Protection (21)

  • Overvoltage / Undervoltage (59/27)

  • Rate of Change of Frequency (ROCOF) (81R)

  • Breaker Failure (50BF)

  • Synchrocheck / Synchronism Supervision (25)

  • Encrypted Protocols – Supports TLS/HTTPS for web access and secure file transfers.

  • Secure IEC 61850 (GOOSE & MMS) – With encryption and authentication for substation communication.

Digital protection relay_edited.png